● Product performance and characteristics
The new generation of OVAY Technology Extra-low Pressure (X) series optimizes the membrane making process of membranes, which has higher water flux and desalination rate compared with the previous generation, and has better pollution resistance. The membrane element is suitable for desalination and advanced treatment of raw water with low salt content, such as surface water, groundwater and tap water with salt content less than 1000 ppm, and can achieve high water yield under extremely low operation pressure or small membrane area. It can be widely used in the second stage of wastewater recycling, purification of drinking water of various scales, boiler make-up water and other fields, and is also an ideal choice in the field of municipal water supply treatment with surface water and well water as water sources.
● Specification parameters
Model of membrane element | Stable desalination rate(%) | Minimum desalination rate(%) | Average water productionGPD(m³/d) | Effective membrane areaft²(㎡) |
OV-X-4040 | 99.2 | 99.0 | 2600(9.8) | 90(8.4) |
OV-X-8040-400 | 99.2 | 99.0 | 12000(45.4) | 400(37.2) |
OV-X-8040-440 | 99.2 | 99.0 | 13200(49.9) | 440(40.9) |
● Testing conditions
Test pressure | 100psi(0.69 MPa) |
Test solution temperature | 25℃ |
Test solution concentration(NaCl) | 500ppm |
Test solution pH value | 7.5 |
Recovery rate of single membrane element | 15% |
● 极限使用条件/Operating and cleanimg limits
Maximum operating pressure | 600psi(4.14 MPa) |
Maximum inlet flow rate | 75gpm (17m³/h) (8040) |
16gpm (3.6m³/h) (4040) | |
Maximum inlet temperature | 45℃ |
Maximum inletSDI15 | 5 |
Inlet free chlorine concentration | <0.1 ppm |
Inlet pH range for continuous operation | 3-10 |
| Inlet pH range for chemical cleaning | 2-12 |
Maximum pressure drop of single membrane element | 15psi(0.1 MPa) |