Material separation nanofiltration membrane OV-NF-S

Field of application
● Material separation
● Reclaimed water reuse
● Zero discharge salt separation
● Garbage leachate
400-9028-699
Product Details

● Product performance and characteristics

Material separation nanofiltration membrane (NF) is an aromatic polyamide composite membrane element for selective desalination. It has a high removal rate for divalent and above ions, organic matter, viruses, etc., but can partially retain monovalent ions such as sodium and potassium. Nanofiltration membrane has the advantages of low pressure and energy efficiency, as it involves no chemical reactions, requires no heating, and preserves biological activity during the separation process. In the design of the membrane element, a 34 mil/46 mil wide channel separator which is easy to clean is adopted. Furthermore, the structural strength of the membrane element is improved so that the element can withstand higher pressure differentials. This series of products has been widely used in industries such as material separation, reclaimed water reuse, zero discharge salt and landfill leachate.



● Specification parameters

Model of membrane element

Stable desalination rate(%)

Average water productionGPD(m³/d)

Effective membrane areaft²(㎡)

OV-NF30-4040S34

≥98.0

2000(7.5)

90(8.4)

OV-NF30-8040S34

≥98.0

10000(37.9)

400(37.2)

OV-NF30-4040S46

≥98.0

1600(6.1)

70(6.5)

OV-NF30-8040S46

≥98.0

8000(30.3)

285(26.5)

OV-NF60-4040S34

≥99.0

1800(6.8)

90(8.4)

OV-NF60-8040S34

≥99.0

9000(34.1)

400(37.2)

OV-NF60-4040S46

≥99.0

1400(5.3)

70(6.5)

OV-NF60-8040S46

≥99.0

7000(26.5)

285(26.5)



● Testing conditions

Test pressure

100psi(0.69MPa)

Test solution temperature

25℃

Test solution concentration(MgSO₄)

2000ppm

Test solution pH value

7.5

Recovery rate of single membrane element

15%



● Operating and cleanimg limits

Maximum operating pressure

600 psi(4.14MPa)

Maximum inlet flow rate

75 gpm (17m³/h)(8040)

16 gpm (3.6m³/h)(4040)

Maximum inlet temperature

45℃

Maximum inleSDI15

5

Inlet free chlorine concentration

<0.1 ppm

Inlet pH range for continuous operation

3-10

Inlet pH range for chemical cleaning

2-12

Maximum pressure drop of single membrane element

15psi(0.1 MPa)